The CP-7000 is a very compact high performance microprocessor 7 zone alarm control panel. The programming is easy to understand with a comprehensive installation guide. Each zone can be programmed with the following options, Timed Entry/Exit, Walk Through, Instant, Personal Alarm, Tamper, Fire, Double Knock, Disabled./Isolate. There are 2 arming modes, Full Guard with the option of programming secure Guard Zones and Part Guard. Secure Zones remain armed when the system is disarmed using user code 6. There are 6 user codes also 1 engineering code. Mains failure and low battery are indicated on the control panel. The unit can be fitted with an optional sleep watch keypad, which enables quick disarming/arming of the system in part guard, also a dedicated panic button is also available on the sleep watch keypad.
• 7 Fully Programmable Zones
• 1 Dedicated Tamper Zone
• Momentary Remote Key Switch Option
• Memory Recall Of Last 50 Activations Indicated By LED's
• Audible Walk Test On All Zones
• Full Guard & Part Guard Arming
• Programmable Service Timer
• Programmable Siren Timer
• Programmable Special Switch Positive
• Programmable Exit Strobe Flashes
• Programmable Engineer Reset And Code Burn In
• Programmable Sleep Watch Remote Keypad Part Guard Arming
PRODUCT SPECIFICATIONS
Automatic Reset
Programmable Functions
Programmable Zone Functions
On all zones with auto isolate on faulted zones
Special Switch Positive
Part Guard
Exit Strobe Flashes
Timed entry/exit
Arming Disarming
Service Timer
Walk Through
Through onboard keypad
Engineer Reset
Instant
Momentary key switch
Engineer Code Burn In
Tamper
Sleep Watch remote keypad
Push Button Final Set
Fire
Sleep Watch Part Guard Arming
Secure
Programmable Timers
Engineer Code X 1
Final Set
Full Guard Entry/Exit Delay: 1-255 seconds
User Codes X 6
Double knock
Part Guard Exit Delay: 1-255 seconds
Sleep Watch
Siren Duration: 1-99 minutes
Zones
Disable/Isolate
Service Timer: 6 weeks, 6 months, 12 months
7 Programmable Zones Positive Loops
Quick Set
100, 200 or 800 events
1 Dedicated Tamper Zone, Negative Loop
Walk Test
Alarm Memory
Outputs
Visual and Audible on all zones
50 Events
Switch Positive, Strobe, Siren
TECHNICAL & ELECTRICAL SPECIFICATIONS
DOWNLOADS
Electrical
Power Supply
Instructions User
Current Consumption
Primary Mains Supply Voltage Rating 230Vac
Quiescent Current <25mA
Secondary Input Voltage Rating 16.5Vac
Alarm Current<150mA
Maximum Total Current Rating: 900mA
Auxiliary Voltage Output: Regulated 13.5Vdc
Rechargeable Backup Batter:
Switched Positive Voltage:
12Vdc Sealed Lead Acid 1.2Amps
When Low: 1.0Vdc
Installation
When High: 12Vdc
Environmental
Bell Voltage Output: 12Vdc
Operating Temperature: -10⁰C to 50⁰C
Speaker Voltage Output: 12Vdc
Storage Temperature: -20⁰C to 60⁰C
Strobe Output: 12Vdc
Maximum Humidity: 95% Non-condensing
Internal Sounder: 0.25Watts, 32 ohms
Brochure
Positive Loop Threshold ( Zones 1-4/PA)
Physical
Minimum Open Resistance: 10K
Dimensions: 260mm X 255mm X 80mm
Maximum Open Resistance: 100K
Housing Material: Plastic ABS/PC 94/VO
Negative Loop Threshold (System Tamper)
Weight: 1.3Kgs
Minimum Open Resistance: 110K
Maximum Closed Resistance: 20K
Complies with the following European standards and regulations:
(EU) Low Voltage Directive LVD 73/23/EEC (amended 93/66/EEC)
Electro Magnetic Compatibility Directive 89/336/EEC Amended by 92/31/EEC and 93/68EEC